A socket port is assigned for the serial port. It’s a 16-bit numbers,
ranging from 1 to 65535. Because the numbers below 1000 are used for
specific purposes (e.g. 80 is for HTTP protocol), we suggest you use
the numbers larger than 1000. Generally the port number 4660 is used
for the serial communication. However you should specify different
port number for each serial port.
Socket type
TCP Server: TCP protocol, passive open, to be connected from the
TCP clients.
TCP Client: TCP protocol, active open, connects to the TCP server.
UDP Client: UDP protocol, connectionless
Remote IP address
The server IP address and socket port would be connected in TCP
Client and UDP Client mode for a certain serial port.
Remote socket port
The server socket port would be connected in TCP Server, TCP Client
and UDP Client mode for a certain serial port.
Interface of serial I/O
It provides an “Auto Detect” function and just depends on the
connected serial device’s interface as RS-422 or RS-485.
Baudrate
Baud Rate: 300 ~ 115200 bps
Parity, Data bits, Stop bit
Parity: None, Even, Odd, Space, Mark.
Data Bits: 5, 6, 7, 8.
Stop Bit: 1 or 2.
Force off-line time
It is for setting the off-line time period of device will be taken when
there is no date input. The parameter can be from “0 to 99” and the
time unit is “Minute”.
Packet Collect Time
It is for setting a packet collecting period of the device serial port’s Tx
and Rx. The parameter can be from “0 to 999” and the time unit is
“mSec”.